Product Submittal: Please refer to the product submittal for additional details and important installation notes: Hydrogen Leak Detector Submittal
• Do NOT exceed 5.7% hydrogen in the mixture with nitrogen.
• Replace batteries before each use.
• Replace sensor at least once per year.
• Store at room temperature in dry location.
The Center 384 Hydrogen Leak Detector is the ideal tool for detecting leak-points in piping systems. As the Center 384 detects hydrogen, the smallest of all the elements, It is particularly well-suited at finding the smallest of leaks, leaks that would take traditional soap bubble test a week to form a visible bubble.
Extremely Sensitive: The Center 384 Trace Gas Leak Detector can detect mixtures of 5% Hydrogen (H2) + 95% Nitrogen (N) with extreme sensitivity.
Semiconductor Sensor and Microprocessor Control: The unit has both a newly developed heated semi- conductor sensor and a microprosessor control to provide reliable digital signal processing.
Adjustable Leak Sensitivity: Adjustable leak sensitivity level and multi-color LED visual indicators also offer the users the ease and convenience of operation.
Additional Ease of Use Features:
• High/Low Leak Sensitivity Selector
• Low Battery Indication
• Semiconductor Gas Sensor
• Detection of Hydrogen
• 15" flexible stainless probe
• Ambient Hydrogen Compensation